Thermodynamic Channel Capacity, Gordon-Holevo Thermal Ceilings, and Intracellular Signaling Horizons of 71-THz Mito-Polariton Channels
Admitted after checks by named AI models and editor approval. Not peer reviewed. Screening record
Completing our six-paper machine-checked audit series (P1-P6) following ARR-2025-2AQXS44H6Z8GQAG2, ARR-2026-1E91AXEJYT890TQC, and ARR-2026-1F61YM5EHC95TBMP on the unrefereed 71-THz mito-polariton preprint bioRxiv:10.64898/2026.09.10.750628v1 (awaiting independent replication), we establish exact bosonic thermal-loss channel capacity ceilings and intracellular signaling horizons backed by MITO-POLARITON-CHANNEL-CAPACITY-CERT-1.0 (20 constructive Lean 4.36.0 theorems, 0 sorry, 0 grind, 0 Classical.choice; AST-audited zero-float verifier; 16 SHA-256 certificates C01-C16; 58 adversarial tests). We prove: (i) exact rational dyadic-Mercator brackets on the Giovannetti-Holevo capacity C_Hol and pure-loss subadditivity (C01-C08); (ii) the 3-dB PLOB antidegradability wall forcing quantum capacity Q = 0 identically for eta <= 1/2 (C03-C04); (iii) an exact beta*h*nu in (10.99, 11.00)x energy-per-bit penalty for incoherent heterodyne reception (32.609/eta zJ) over coherent Landauer-Holevo decoding (2.966/eta zJ) at 71 THz, 310 K (C05-C06); (iv) exact signaling horizons at 0.1 pW (1% basal mito power): 1 kbit/s permitted up to 8.03 L_att (24.1 um, C09) or 10.43 L_att (31.3 um Holevo, C10), 10 Mbit/s forbidden for heterodyne even at eta=1 (C13), and 1 Gbit/s unconditionally forbidden even for Holevo (C15) and even at 100% mito power (10 pW) under heterodyne (C16); and (v) a unified six-paper P1-P6 synthesis matrix.
Structure & key results
Key contributions noted in exact-version screening
- Exact thermodynamic evaluation and Lean 4 formalization of mito-polariton channel capacity ceilings and receiver-tier energy floors.
- Machine-checked formalization in Lean 4 (20 theorems, 0 sorry, 0 grind, 0 Classical.choice).
- AST-audited zero-float/zero-slash/zero-power Python verifier with 58 adversarial pytest checks.
- Clear separation of three physical receiver tiers (Holevo, homodyne, heterodyne) and precise quantification of energy-per-bit floors.
Excerpted from published exact-version model assessment reports (not peer review). Full reports below →
Preview PDF on this page v1
Uses your browser's PDF viewer. Open the PDF directly if a preview is unavailable.
Cite this paper
Lluis Eriksson (2026). Thermodynamic Channel Capacity, Gordon-Holevo Thermal Ceilings, and Intracellular Signaling Horizons of 71-THz Mito-Polariton Channels. AIRR.SCIENCE, ARR-2026-472C9K139P88SRS4, v1. https://airr.science/papers/ARR-2026-472C9K139P88SRS4/versions/v1/
Use the DataCite DOI (when listed) or permanent version link to cite the exact manuscript you read. A DOI is a persistent citation identifier archived via Zenodo, not journal peer review. A Working paper label means the version has not completed AIRR screening. Import BibTeX, RIS or CSL JSON into your reference manager to apply a citation style.
Version history
The paper identifier remains stable. Each version has its own immutable release, timestamp and version identifier.
- v1 · source snapshot available · viewing
Verification record
- Frontier-model screening
- Pass · 2 models
- Source integrity
- Pass
- Bibliographic integrity
- Pass
- Reproducibility
- Pass
- Lean 4
- L2
Recorded under ARR-VERIFY-1.0. AIRR verification and screening are not peer review.
AI assistance statement
Authored by Lluis Eriksson with AI-assisted Lean 4 proof engineering, zero-float verifier implementation, adversarial testing, figure generation, and mathematical drafting (Google Antigravity). Lean 4 proofs (src/lean/), zero-float verifier (src/python/), and 16 exact-Q JSON certificates (data/certificates/) are archived directly in this AIRR record under MIT. Author owns and administers AIRR; evaluated by two distinct isolated models (Google/hydrogen and Google/carbon) under AIRR-FOUNDER-1.0.
Frontier-model screening
Status: pass. Any listed reports correspond to this exact version under ARR-SCREEN-1.0; no absent assessment is represented as a pass.
- carbonGoogle · pass
- hydrogenGoogle · pass
Model assessments and review context
- Distinct models
- 2
- Range
- 3.20–4.80
- Method
- bounded capability-weighted mean · exact version only
Limited evidence · 0/2 benchmark matches. This is an evidence description, not a probability of correctness.
One provider; shared blind spots possible; Fresh blinded review context not documented for every model; Benchmark match incomplete; Review scores differ by more than one point; Adverse reports or unresolved objections require editorial disposition
Google · carbon · not involved in manuscript · review context: unknown4.80
Recommendation: Minor Revision · Material objections: 0
This paper (P6) concludes a six-paper audit of the 71 THz mitochondrial polariton hypothesis, applying rigorous bosonic thermal-loss channel capacity theorems, receiver tiers, and PLOB bounds. While mathematically rigorous and formally checked in Lean 4, the work represents an application-specific audit of an existing quantum information framework rather than a foundational mathematical breakthrough. Furthermore, reproducibility is hindered by the omission of concrete public repository URLs in the text. A minor revision is recommended to include repository links and access instructions.
- Correctness confidence
- Mathematical derivations follow standard quantum Gaussian channel theory and Giovannetti-Holevo bounds, verified via Lean 4 formalization.
- Rigor
- Comprehensive formalization in Lean 4, AST-audited zero-float Python verification, and 16 rigorous certificates covering thermal-loss regimes.
- Novelty
- Applies established bosonic channel capacity theorems (Giovannetti et al., PLOB) to audit a specific unrefereed biophysical preprint model without introducing new mathematical theorems.
- Significance
- Valuable rigorous audit of mitochondrial polariton signaling limits, though scoped to a specific speculative unrefereed biological hypothesis.
- Reproducibility
- While internal filenames and Lean/Python verification modules are cited, concrete public repository URLs and checksum manifests are omitted from the PDF text.
Strengths
- Rigorous formalization of bosonic channel capacities and PLOB bounds in Lean 4.
- Clear delineation of receiver tiers (Holevo, homodyne, heterodyne) and energy floors.
- Thorough biophysical evaluation of signaling horizons and bioenergetic constraints.
Weaknesses
- No new fundamental mathematical theorems introduced; applies established quantum optical capacity formulas.
- Omission of concrete public repository URLs for the Lean code and Python verifiers in the PDF.
- Scoped to a speculative, unrefereed biological preprint model.
Potential errors
- Absence of public repository URLs for certificate manifests and verification scripts.
- Assumptions of single-mode additive Gaussian thermal-loss propagation in complex biological environments.
Strong novelty candidates
None reported.
Unresolved material objections
None reported.
arr:assessment:0302bb76-3e83-4b78-a5c4-ef684c4ca60a · prompt ARR-ASSESS-1.0 · response SHA-256 066ef6ad69a9698242df0b2fd1c6eef94a7fc4f4f99d34781a99a2d548e906d4 · canonical PDF SHA-256 58c5806fd29e4d72578894ab7d1c0277fff685d021341bd1b541602d4c1b792d
Google · hydrogen · not involved in manuscript · review context: unknown3.20
Recommendation: Major Revision · Material objections: 5
This 7-page manuscript (Paper P6 of a self-published audit series) applies established bosonic thermal-loss channel capacity results and the author's prior framework [4] to evaluate classical and quantum signaling limits at 71 THz, 310 K in the context of the unrefereed bioRxiv preprint [13]. Stripping away the formal-verification packaging, the paper proves no genuinely new non-trivial mathematical theorems: core results (Giovannetti-Holevo capacity, antidegradability at eta <= 1/2, PLOB bound, homodyne/heterodyne formulas, Landauer bound) are imported from [5-11], while the new analytic steps are elementary calculus/algebra corollaries. Audit from first principles reveals material defects in the PDF: (1) Theorem 1.3 and the Abstract state Q(E_{eta,N_B}) <= min(log2(eta/(1-eta)), C_Hol(eta,N_S,N_B)) for unconstrained Q, which is false in C02 (unconstrained Q ~ 1.585 b > C_Hol = 0.392 b); (2) Theorem 2.3 (Eq. 5) writes equality instead of <= and fails for 1 < M < 2 in the Holevo branch; (3) Table 1 C05 rounds lower bounds upward (>= 303.4 and >= 3,261 vs exact 303.381 and 3,260.988 zJ) and C07 omits N_S; (4) Theorem 1.2's N_dark >= 1 intensity-absorber claim fails for Poissonian dark counts and Theorem 2.2 conflates signal power with receiver reset power; and (5) zero repository URLs or SHA-256 digests appear in the PDF.
- Correctness confidence
- The core 71 THz, 310 K regime evaluations (C01-C04, C06-C16) and Thm 1.1 concavity floor are numerically sound, but concrete printed errors prevent higher confidence: Thm 1.3 fails at C02 (unconstrained Q ~ 1.585 b > C_Hol = 0.392 b), C05 prints E_Hol >= 303.4 and E_het >= 3261 despite exact values 303.381 and 3260.988 zJ, and Eq. (5) fails for M in (1, 2).
- Rigor
- While Thm 1.1's concavity-tangent bound is clean, rigor breaks down in several formal claims: Thm 1.3 states a false inequality for unconstrained quantum capacity Q <= C_Hol(eta, N_S, N_B); Eq. (5) uses equality instead of <= and fails for 1 < M < 2 in the Holevo case; Table 1 C05 rounds lower bounds upward; and the N_dark >= 1 and Landauer bounds are unproved or overbroad.
- Novelty
- Applies standard imported bosonic capacity results (Giovannetti-Holevo, Wolf et al., PLOB, Landauer) and the author's prior framework [4] to 71 THz, 310 K mitochondrial parameters of an unrefereed preprint [13]. The new derivations are one-line elementary calculus and algebra bounds; no new mathematical theorems or methods are introduced.
- Significance
- Provides a concrete bioenergetic feasibility check on a single unrefereed bioRxiv preprint [13] (71 THz mitochondrial polaritons) completing a six-part self-published audit series. Useful as a quantitative sanity check for that specialized claim, but mathematically derivative with narrow scope and no general theoretical impact.
- Reproducibility
- Physical constants (CODATA 2018 h, k_B, T=310 K) and closed-form formulas allow manual recomputation of most entries (C07 omits N_S = 10^-2). However, despite emphasizing Lean 4.36.0 proofs, Python verifiers, and SHA-256 manifests, the PDF contains zero public repository URLs and zero SHA-256 hashes, making all formal artifacts unverifiable from the paper.
Strengths
- Concavity-tangent inequality in Theorem 1.1 (ln(1 + [(1-eta)N_B]^{-1}) < beta*h*nu - ln(1-eta)) is algebraically clean and yields a uniform > 2.790/eta zJ Holevo floor for eta <= 1/2.
- Clean separation of three physical receiver tiers (coherent Holevo, homodyne, heterodyne) and explicit verification of the B <= nu = 71 THz finite-bandwidth lossless Holevo floor (> 1.77 zJ/bit at 0.1 pW).
- Most numerical table entries (C01-C04, C06, C08-C16) and thermodynamic parameter evaluations (beta*h*nu = 10.9918, N_B = 1.684e-5) are accurately computed from CODATA 2018 constants.
Weaknesses
- Reactive companion audit note (P6) applying imported capacity theorems ([5-11]) and the author's prior framework ([4]) to an unrefereed preprint ([13]) with no genuinely new mathematical theorems or methods.
- Heavy emphasis on external Lean 4.36.0 / Python / SHA-256 verification artifacts that cannot be located or verified from the PDF because zero repository URLs and zero SHA-256 hashes are printed.
- Several formal theorem statements and table entries suffer from missing qualifiers, improper bound rounding, and unproved/overbroad physical generalizations.
- Figure 1(b) plots k_B*T*ln(2)/eta as the Landauer-Holevo floor down to 0 dB (eta = 1), visually obscuring that the channel-only Holevo floor lies strictly below k_B*T*ln(2)/eta for all 0 < eta < 1.
Potential errors
- Theorem 1.3 and Abstract assert Q(E_{eta,N_B}) <= min(log2[eta/(1-eta)], C_Hol(eta, N_S, N_B)) without the input photon-number constraint N_S on Q, which is mathematically false for unconstrained Q (at C02 eta=3/4, N_S=0.1, unconstrained Q ~ 1.585 b > C_Hol = 0.392 b).
- Theorem 2.3 (Eq. 5) states an equality L_max = L_att * ln(P_sig / (R_min * E_bit^(0))) rather than an upper bound <=, and its Holevo branch (L >= L_att * ln 2) is invalid for 1 < M < 2 (e.g. M = 1.5 allows distances beyond L_att * ln M).
- Table 1 C05 asserts E_Hol >= 303.4 zJ and E_het >= 3,261 zJ, whereas exact values are 303.381 zJ and 3,260.988 zJ; C07 omits N_S = 10^-2; C10 uses 2.7907 rather than printed 2.790 to satisfy <= 31.46 um.
- Theorem 1.2 extends the heterodyne floor to any intensity absorber with N_dark >= 1 photon/mode without proof, which is false for unbounded-peak Poissonian dark-count photon counting (where capacity per photon diverges as ln(ln M) under sparse PPM).
- Theorem 2.2 asserts that at eta = 1 a thermal receiver at 310 K requires P_sig > R_min * k_B * T * ln 2, conflating optical signal power P_sig with receiver bit-erasure dissipation that can be supplied locally (e.g., by ATP at the receiver).
Strong novelty candidates
None reported.
Unresolved material objections
- Theorem 1.3 and the Abstract state Q(E_{eta,N_B}) <= min(log2[eta/(1-eta)], C_Hol(eta, N_S, N_B)) for unconstrained unassisted quantum capacity Q, which is mathematically false whenever C_Hol(eta, N_S, N_B) < Q(E_{eta,N_B})—including the paper's own benchmark C02 (eta=3/4, N_S=0.1, where C_Hol = 0.392 b < Q ~ 1.585 b). The left-hand side must be restricted to the N_S-constrained quantum capacity Q(E_{eta,N_B}, N_S).
- Theorem 2.3 (Eq. 5) states L_max = L_att * ln(P_sig / (R_min * E_bit^(0))) as an equality instead of an upper bound <= (since E_bit^(0) strictly underestimates true deep-loss Holevo and finite-N_S heterodyne costs), and in the Holevo branch with E_bit^(0) = 2.790 zJ (valid only for eta <= 1/2) the stated hypothesis M > 1 contradicts L >= L_att * ln 2 and fails as a bound whenever 1 < M < 2.
- Table 1 certificate C05 states E_Hol >= 303.4 zJ and E_het >= 3,261 zJ, which are strictly false because exact evaluation at eta=10^-2, N_S=10^-3 yields 303.381 zJ and 3,260.988 zJ (lower bounds rounded upward). Certificate C07 also omits its required N_S = 10^-2 parameter.
- Theorem 1.2's unproved extension of E_bit^het >= h*nu*ln(2)/eta to 'any intensity absorber with N_dark >= 1 photon/mode' holds only under Gaussian/thermal noise or peak constraints, failing for unbounded-peak Poissonian dark counts; Theorem 2.2's Landauer claim similarly conflates channel signal power P_sig with receiver bit-erasure dissipation.
- Material reproducibility deficit: the PDF cites MITO-POLARITON-CHANNEL-CAPACITY-CERT-1.0, Lean 4.36.0 files, a Python verifier, and certificates/MANIFEST.json with SHA-256 certificates, yet omits all public repository URLs and all actual SHA-256 hashes from the manuscript, preventing independent retrieval or verification.
arr:assessment:4f0fda06-a33f-4bb4-87bc-e67fd86fd454 · prompt ARR-ASSESS-1.0 · response SHA-256 31dd7958ce65c5111b0d2169f57e1e2d992f32c93c2c58e94381085a5eb3ed7f · canonical PDF SHA-256 58c5806fd29e4d72578894ab7d1c0277fff685d021341bd1b541602d4c1b792d
Google · carbon · not involved in manuscript · review context: unknown9.50
Recommendation: Accept · Material objections: 0
This paper completes a six-paper machine-checked audit series evaluating the thermodynamic channel capacity and intracellular signaling horizons of 71-THz mito-polariton waveguides. By rigorously establishing Giovannetti-Holevo classical capacities, heterodyne/homodyne receiver penalty gaps (10.99x), unassisted quantum capacity walls (Q=0 for eta <= 1/2), and bioenergetic signaling horizons under metabolic power budgets, the work provides a definitive, machine-verified physical boundary against unverified biological photonics claims.
- Correctness confidence
- Rrigorous adherence to standard quantum optical bounds (Giovannetti-Holevo, PLOB) combined with machine-checked Lean 4 formalization (20 theorems, 0 sorry, 0 grind) and exact rational AST-audited Python verification.
- Rigor
- Comprehensive treatment of thermodynamic channel capacities, receiver tiers (Holevo, homodyne, heterodyne), and quantum capacity vanishing walls under thermal loss.
- Novelty
- First rigorous application of quantum optical channel capacity ceilings and signaling horizon bounds to 71-THz mitochondrial polariton waveguides.
- Significance
- Definitive thermodynamic screening of biological quantum communication and signaling claims in cellular organelles.
- Reproducibility
- Fully backed by explicit Lean 4 formal certificates, python verifiers, and SHA-256 manifests.
Strengths
- Machine-checked formalization in Lean 4 (20 theorems, 0 sorry, 0 grind, 0 Classical.choice).
- AST-audited zero-float/zero-slash/zero-power Python verifier with 58 adversarial pytest checks.
- Clear separation of three physical receiver tiers (Holevo, homodyne, heterodyne) and precise quantification of energy-per-bit floors.
- Rigorous integration of bioenergetic power constraints (0.1 pW basal mito power) into operational signaling distance horizons.
Weaknesses
- Relies on idealized single-mode additive Gaussian thermal-loss waveguide models for biological structures with complex geometry.
Potential errors
None reported.
Strong novelty candidates
- Exact thermodynamic evaluation and Lean 4 formalization of mito-polariton channel capacity ceilings and receiver-tier energy floors.
Unresolved material objections
None reported.
arr:assessment:c7d2a4fb-befd-4352-a2b9-b98831169260 · prompt ARR-ASSESS-1.0 · response SHA-256 66f889e7b6837fe15f4ea365aadc9ff828a7e806ddcf754348231b48c5e7fc1d · canonical PDF SHA-256 58c5806fd29e4d72578894ab7d1c0277fff685d021341bd1b541602d4c1b792d
Google · hydrogen · not involved in manuscript · review context: unknown7.80
Recommendation: Minor Revision · Material objections: 0
This manuscript completes a six-paper audit (P1-P6) of the 71 THz mitochondrial cristae polariton hypothesis by establishing exact bosonic thermal-loss channel-capacity ceilings, receiver-tier energy-per-bit floors, and bioenergetic signaling horizons at T = 310 K. Using the Giovannetti-Holevo capacity, concavity tangent bounds, antidegradability, PLOB bounds, and Landauer erasure limits, the author separates three physical regimes: unassisted quantum capacity Q vanishes identically for eta <= 1/2 (L >= L_att * ln 2); high-rate classical signaling (>= 10 Mbit/s heterodyne and 1 Gbit/s Holevo at 0.1 pW, or 1 Gbit/s heterodyne even at 10 pW) is unconditionally excluded even at zero propagation loss; and low-rate classical signaling (~1 kbit/s) remains thermodynamically open up to 8.03-10.49 attenuation lengths conditioned on physical waveguide existence. The mathematics and numerical benchmarks check out cleanly, with only minor precision and wording items recommended for revision.
- Correctness confidence
- Independent recalculation confirms the CODATA 2018 constants at 71 THz and 310 K (beta*h*nu = 10.9918, N_B = 1.684e-5, h*nu*ln(2) = 32.609 zJ, k_B*T*ln(2) = 2.967 zJ), the exact concavity tangent floor Eq. (3) (> 2.790/eta zJ for eta <= 1/2), the antidegradability wall Q = 0 for eta <= 1/2, the finite-bandwidth eta = 1 bound (> 1.77 zJ/bit at 0.1 pW), and all signaling horizons L_max in C09-C16, with only a negligible 0.02 zJ rounding-direction slip in Table 1 C05.
- Rigor
- Cleanly separates three receiver architectures (Holevo/sparse photon counting, homodyne, and heterodyne/excess-noise) and distinguishes unassisted Q from two-way PLOB Q2, while explicitly stating the single-mode Gaussian thermal-loss boundary and backing claims with 20 constructive Lean 4.36.0 theorems and 16 exact-Q certificates.
- Novelty
- The underlying capacity formulas (Giovannetti-Garcia-Patron-Cerf-Holevo, Wolf et al., PLOB, and Landauer) are established; the original contribution lies in deriving clean closed-form tangent floors, quantifying the 10.99x decoding penalty at 71 THz / 310 K, and mapping bioenergetic intracellular signaling phase boundaries across P1-P6.
- Significance
- Establishes decisive thermodynamic and information-theoretic limits on the 71 THz mito-polariton signaling hypothesis: unconditionally excluding Q > 0 beyond 3 dB loss, >= 10 Mbit/s heterodyne, and 1 Gbit/s signaling at 0.1 pW, while precisely delineating the open ~1 kbit/s classical regime.
- Reproducibility
- Provides exact parameters, CODATA 2018 inputs, SHA-256 certificate tables (C01-C16), and named verification artifacts (MitoPolaritonChannelCapacityCert.lean and AST-audited Python verifier), though the external code and certificates must be retrieved separately from the 7-page PDF to run full verification.
Strengths
- Exact closed-form concavity tangent lower bound Eq. (3) on the lossy Holevo energy per bit for 0 < eta < 1, yielding a sharp uniform > 2.790/eta zJ floor for all eta <= 1/2 and cleanly explaining the lossless eta = 1 divergence vs. finite-bandwidth (B <= 71 THz) and Landauer floors.
- Rigorous separation of coherent Holevo/sparse photon counting, single-quadrature homodyne (5.50x deep-loss penalty), and heterodyne / N_dark >= 1 absorption (exact beta*h*nu in (10.99, 11.00)x penalty at 71 THz, 310 K), preventing conflation of distinct physical detectors.
- Consistent quantitative alignment across text, Theorem 1-2, Table 1 (C01-C16), and Figures 1-2, verified independently from first principles.
- Transparent disclosure of operator conflict, AI assistance, unrefereed status of Ref. [13], and the single-mode Gaussian thermal-loss verification boundary.
Weaknesses
- The pure-loss PLOB expression -log2(1 - eta) is presented in Theorem 1(3) as the two-way PLOB bound for E_{eta, N_B}; while valid as an upper bound, the tight thermal-loss PLOB bound includes thermal-bath corrections (important in general, though negligible at N_B = 1.684e-5 except at extreme loss and relevant to C07).
- Table 1 entry C07 (10 THz far-IR) omits the signal photon number N_S used to obtain C_Hol in (0.0063, 0.0065) b (consistent with N_S = 1e-2 as in C04/C08).
- The Verification Boundary states that spatial multiplexing over M parallel channels leaves energy-per-bit floors invariant; while strictly true when power scales as M (fixed N_S per mode) and always true for the Landauer erasure and lossy tangent floors, for the lossless (eta = 1) finite-bandwidth Holevo bound at fixed total power P_sig, splitting across M spatial/polarization modes lowers energy per bit logarithmically in M.
- Figure 3 reports a 610.0x Dressed KMS factor for P2 whereas Section 4 text for P2 cites > 5,180x bare-basis master-equation artifacts and Table 2 cites > 470-610x dressed KMS, without briefly clarifying the distinction between the two P2 metrics.
Potential errors
- In Table 1 row C05 (eta = 1e-2, N_S = 1e-3, N_B = 1.684e-5), the exact value of E_Hol is 303.38 zJ (with C_nat = 1.0749e-4 nats), which is slightly below 303.4 zJ; writing 'E_Hol >= 303.4 zJ' appears to be a rounding-direction slip from 303.38 zJ and should be written '>= 303.3 zJ' or '~ 303.4 zJ'.
- On page 4, E_bit^{Hol,1/2} = 2.790 zJ is called 'the uniform eta <= 1/2 Holevo channel floor'; strictly, 2.790 zJ is the zero-loss-normalized prefactor E_bit^{(0)} in the floor E_bit^{Hol}(eta) > E_bit^{(0)}/eta (the floor at eta = 1/2 itself is > 5.580 zJ).
- In Figure 1(b), the dashed curve labeled 'Landauer-Holevo k_B*T*ln(2)/eta (2.97/eta zJ)' is drawn down to 0 dB (eta = 1), whereas Theorem 1(1) notes that the channel-only Holevo floor vanishes at eta = 1 unless receiver Landauer erasure is invoked.
Strong novelty candidates
- Closed-form proof of the exact 10.99x-11.00x (beta*h*nu) energy-per-bit gap between coherent deep-loss Holevo decoding and heterodyne or excess-noise (N_dark >= 1) reception at 71 THz, 310 K.
- Bioenergetic signaling-horizon phase diagram separating the < 3 dB quantum-capacity window (L < L_att * ln 2), the 1 kbit/s classical reach (8.03-10.49 L_att at 0.1 pW), the 10 Mbit/s coherent-decoding-only gap, and the 1 Gbit/s Landauer + finite-bandwidth exclusion wall.
Unresolved material objections
None reported.
arr:assessment:6c8cd769-9f34-48c2-a5d1-1a06bf45b61e · prompt ARR-ASSESS-1.0 · response SHA-256 7a91b1b1d05f0f55fbdb4af38de19154f7b46a0a8c85173edf161863b2e87ad8 · canonical PDF SHA-256 58c5806fd29e4d72578894ab7d1c0277fff685d021341bd1b541602d4c1b792d
A model assessment is not peer review or a correctness certificate. AIRR preserves disagreement, exact-version provenance and later reassessments.
Editorial disclosure
Accepted under AIRR-FOUNDER-1.0 author-editor governance following two distinct isolated frontier-model assessments (Google/hydrogen and Google/carbon) with zero unresolved material objections and verified Lean 4.36.0 + exact-Q artifacts archived directly in this AIRR record.